Battery storage system · Residential
HeroEE 16
LiFePO4 · 16.08 kWh usable · CEC listed
Simple & Reliable
- Useable Battery Capacity*
- 16.08 kWh
- Rated DC Power
- 8.04 kW
- Max Charge/Discharge Power
- 10.24 kW
- Battery Cell Lifespan
- ≥ 11,000 cycles
*DC usable energy. Test conditions: 100% DoD, 0.5C charge/discharge at 25 °C, at the beginning of service life. Actual system usable energy may vary with different settings.

Inside · HiTHIUM ESS cell, 314 Ah
Sixteen prismatic cells. One purpose.
- Cell
- 314 Ah
- Energy
- 1,004.8 Wh
- Voltage
- 3.2 V
- Config
- 16S1P
540.6 × 240 × 781.2 mm · 117.6 kg · IP30 · Floor-mounted
The same cell the grid runs on.
Inside every HeroEE 16 sit sixteen HiTHIUM 314 Ah prismatic LFP cells: the same Grade-A cell HiTHIUM builds for utility-scale storage. In the 2025 global rankings from InfoLink, SMM and ICC, HiTHIUM placed Top 2 worldwide for energy-storage battery shipments and Top 2 for utility-scale (BESS) battery shipments, with more than 100 GWh delivered to date. The cell the grid buys is the cell in your garage.
- 314 AhPrismatic LFP, Grade-A, 16S1P
- ≥ 11,000Cell cycles at 100% DoD, 25 °C
- Top 2Global energy-storage and utility-scale BESS battery shipments, 2025
- 100 GWhCumulative HiTHIUM shipments
| Usable battery capacity* | 16.08 kWh |
|---|---|
| Rated voltage | 51.2 VDC |
| Battery cell | 314 Ah LFP (LiFePO4), 16S1P |
| Battery cell lifespan | ≥ 11,000 cycles |
| Rated DC power | 8.04 kW |
| Rated charge / discharge current | 157 A |
| Max charge / discharge power | 10.24 kW |
| Max charge / discharge current | 200 A, 1 h continuous |
| Cooling | Natural cooling |
| IP rating | IP30 |
| Dimensions (L × W × H) | 540.6 × 240 × 781.2 mm |
| Weight | Approx. 117.6 kg |
| Installation | Floor-mounted |
| Built-in communication ports | CAN / RS485 / RS232 |
| Scalable | Up to 16 batteries in parallel, 256 kWh |
| Protection | Over-temperature, under-temperature, over-charge, over-current, short-circuit, under-voltage, reverse-connection and fault protection |
| Certification | UN 38.3 · MSDS · IEC 62619 · IEC 62040 |
*DC usable energy. Test conditions: 100% DoD, 0.5C charge/discharge at 25 °C, at the beginning of service life. Actual system usable energy may vary with different settings.
The above is for reference only; the specification sheet shall prevail.
Downloads
Everything in writing.
Installation references, warranty terms, the datasheet, the inverter compatibility statement and the TÜV certificates, for installers, certifiers and owners.
HiTHIUM · HeroEE 16 · Residential battery