Legend 112C
HiTHIUM HeroEE · Commercial & industrial ESS· MODEL LEGEND-112C

Legend 112C

A turnkey 112.5 kWh outdoor battery cabinet for commercial & industrial sites. LiFePO4 chemistry, 358.4 V system voltage, modular DC/AC split, IP55 enclosure — engineered to deploy fast and run for 11,000 cycles.

Rated energy
112.5kWh
Rated voltage
358.4V
Power rating
56kW
@ 70% SOH, 0.5 P
11,000cycles
System overview

A complete C&I storage block, ready to deploy.

Legend 112C consolidates 112 LiFePO4 cells in a 1P112S configuration into a single outdoor cabinet. DC/AC split design, integrated thermal management, aerosol fire suppression, and an IP55 enclosure — sized for car-park, micro-grid, peak-shaving, and behind-the-meter installations.

UN38.3IP55C3 corrosionAerosol FSS485 / CAN / Ethernet
A complete C&I storage block, ready to deploy.
Rated energy
112.5kWh
Rated capacity
314Ah
C/D ratio
0.5P
DC-side efficiency
≥ 93%
Cycle life @ 70% SOH
11,000
Built to run, outside, for a decade.
Designed for the field

Built to run, outside, for a decade.

IP55 enclosure, C3 corrosion grade, < 75 dB acoustic profile, and a charge window that opens at 0 °C and discharges down to −20 °C.

High-efficiency energy management

High-efficiency energy management

Adaptive thermal-management algorithm holds cells inside the optimal SOC band, lifting round-trip efficiency and protecting capacity over 11,000 cycles.

≥ 93% DC-side efficiency
Safety & reliability

Safety & reliability

Aerosol-based fire-suppression, integrated temperature and smoke sensors, and a steel enclosure rated to C3 corrosion environments. Five-layer protection chain across temperature, charge and current.

5Layer protection chain
Aerosol Fire Extinguishing

Aerosol Fire Extinguishing

The cabinet is equipped with an integrated aerosol fire extinguisher. Upon detecting high temperature, the system activates automatically and fully suppresses the fire within 5 seconds — minimising risk and protecting the installation without manual intervention.

5sec auto-suppression
Intelligent Air-Cooling System

Intelligent Air-Cooling System

The cooling system activates automatically, drawing heat away from the cell stack. Cooling stops once the maximum cell temperature returns to 25 °C, reducing energy draw and extending fan life.

30 → 25°C activation window
Inside the cabinet

Six layers, one enclosure.

The Legend 112C is a vertically integrated stack — the battery, BMS, DC bus, cooling, fire-suppression and comms-gateway are designed and tested as a single unit, not assembled on site.

01Battery stack1P112S · 314 Ah · LiFePO4
02BMSCell-level voltage / temperature monitoring
03DC bus302.4–408.8 V operating window
04Air coolingActive thermal management, < 75 dB
05Fire suppressionAerosol FSS + smoke detection
06Comms gateway485 · CAN · Ethernet
Six layers, one enclosure.
Documents

Documentation

Datasheets, certifications, and installation guides for engineering and procurement teams.

Datasheet

Legend product datasheet.

Full electrical, mechanical, and environmental specifications.

PDF / ENDownload

Upload final PDFs to Shopify Files and reference their URLs here.

Product details

Full data sheet.

Every published specification, exactly as it appears on the official ELEXTRA datasheet for the Legend 112C. Values are typical at 25 °C unless stated otherwise.

The above is for reference only; the official specification sheet shall prevail.
ModelHeroEE Legend 112C
Battery typeLiFePO4
Compound mode1P112S
Rated energy112.5 kWh
Rated capacity314 Ah
Battery cycles11,000 cycles @ 25 °C, 100% DoD, 0.5 P, 70% SOH
Rated voltage358.4 V
Power rating56 kW
Rated charge / discharge ratio0.5 P
Operating voltage range302.4 – 408.8 V
Standard charge / discharge current157 / 157 A
Type of coolingAir cooling
Fire-protection systemAerosol
ProtectionOver-temperature / Under-temperature / Overcharge / Overcurrent / Undervoltage
Operating temperatureCharging 0 °C – 55 °C · Discharging −20 °C – 55 °C
Storage temperature−20 °C – 60 °C
Noise< 75 dB
Size (W × D × H)900 × 1000 × 2280 mm
Weight1,400 kg
Corrosion resistance gradeC3
Ingress protectionIP55
Allowable relative humidity0 – 95 % (no condensation)
Allowable altitude above sea level≤ 4000 m (derated above 2000 m)
DC-side efficiency≥ 93 %
Communication interfaceRS-485 · CAN · Ethernet
Approval standardsUN38.3
Peak shaving
01

Peak shaving

Shift on-site load away from peak tariff windows, reducing demand charges for industrial and large commercial sites.

Solar self-consumption
02

Solar self-consumption

Capture surplus PV during the day, dispatch into evening base-load. Three-phase AC coupling supported.

Backup & islanding
03

Backup & islanding

Black-start capable. Maintains critical loads during grid outages with sub-second changeover via the integrated controller.

VPP & grid services
04

VPP & grid services

Native CSIP-AUS readiness. Participate in frequency control, FCAS markets, and aggregator dispatch via Ethernet.

Next step

Ready to deploy.

Speak with an ELEXTRA engineer to size, certify and commission a Legend 112C block on your site.

Download datasheetRequest quote